Assessment Year | 2012 |
---|---|
Principal Product | Aluminum castings |
NAICS | 331524: Aluminum Foundries (except Die-Casting) |
SIC | 3365: Aluminum Foundries |
Sales Range | less than $500 k |
# of Employees | 14 |
Plant Area |
16,000
ft2
|
Annual Production | 89,562
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $63,670 | 675,300 |
kWh
|
$0.094 |
Electricity Demand | $16,534 | 3,045 |
kW-mo/yr
|
$5.43 |
Natural Gas | $2,351 | 241 |
MMBtu
|
$9.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,021 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $199 | $640 |
$149
1,579
kWh
|
$49
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,134 | $5,290 |
$852
9,011
kWh
|
$282
-
kW-mo/yr
|
|
03 | 2.6241: Reduce temperature of process equipment when on standby | $688 | - |
$688
7,282
kWh
|
- | |
04 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $7,949 | $1,660 |
$7,949
83,670
kWh
|
- | |
TOTAL RECOMMENDED | $9,969 | $7,590 |
$9,638
101,542
kWh
|
$332
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $2,021 | $5,930 |
$1,689
17,872
kWh
|
$332
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs