Assessment Year | 2012 |
---|---|
Principal Product | HVAC parts |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $50 M to 100M |
# of Employees | 211 |
Plant Area |
250,000
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $217,294 | 2,938,282 |
kWh
|
$0.074 |
Electricity Demand | $29,370 | 10,032 |
kW-mo/yr
|
$2.93 |
Natural Gas | $91,939 | 22,376 |
MMBtu
|
$4.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,495 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $532 | $800 |
$434
5,867
kWh
|
$98
-
kW-mo/yr
|
- | |
02 | 2.7492: Use proper thickness of insulation on building envelope | $1,179 | $11,250 | - | - |
$1,179
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,833 | - |
$1,833
24,767
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $2,252 | $2,400 |
$1,837
24,821
kWh
|
$415
-
kW-mo/yr
|
- | |
05 | 2.4322: Use or replace with energy efficient substitutes | $698 | $1,200 | - | - |
$698
-
MMBtu
|
|
TOTAL RECOMMENDED | $6,495 | $15,650 |
$4,104
55,455
kWh
|
$513
-
kW-mo/yr
|
$1,877
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs