ITAC Assessment: MUCM25
ITAC logo
ITAC Assessment: MUCM25
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Medical Office
NAICS 621111: Offices of Physicians (except Mental Health Specialists)
SIC 8011: Offices and Clinics of Doctors of Medicine
Sales Range less than $500
k
# of Employees 30
Plant Area 11,500
ft2
Annual Production 1
units
Production Hrs. Annual 2,912
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $5,362 69,840
kWh
Electricity Demand $4,594 207
kW-mo/yr
Electricity Fees $2,476 -
Natural Gas $1,821 201
MMBtu
Other Gas $109 1
MMBtu
Waste Disposal Costs
Water Usage $7,675 33
Tgal
TOTAL YEARLY COSTS $22,036
RECOMMENDED SAVINGS* $4,282 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7111: Reduce illumination to minimum necessary levels $182 - $55
693
kWh
$127
-
kW-mo/yr
-
02 2.7134: Use photocell controls $92 $401 $43
543
kWh
$49
-
kW-mo/yr
-
03 2.7135: Install occupancy sensors $350 $1,478 $163
2,043
kWh
$187
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $43 - $16
203
kWh
$27
-
kW-mo/yr
-
05 2.7291: Reschedule and rearrange multiple-source heating systems $359 - $51
637
kWh
- $308
-
MMBtu
06 2.7444: Close holes and openings in building such as broken windows $193 $307 $140
1,744
kWh
$53
-
kW-mo/yr
-
07 2.7492: Use proper thickness of insulation on building envelope $1,443 $13,685 $188
2,356
kWh
$215
-
kW-mo/yr
$1,039
-
MMBtu
08 2.9114: Use solar heat to make electricty $1,620 $12,320 $877
10,967
kWh
$743
-
kW-mo/yr
-
TOTAL RECOMMENDED $4,282 $28,191 $1,535
19,185
kWh
$1,401
-
kW-mo/yr
$1,347
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs