ITAC Assessment: MUCM15
ITAC logo
ITAC Assessment: MUCM15
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product n/a
NAICS 444130: Hardware Stores
SIC 5251: Hardware Stores
Sales Range $5
M
to 10
M
# of Employees 4
Plant Area 23,150
ft2
Annual Production 1
units
Production Hrs. Annual 2,340
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $7,687 66,327
kWh
Electricity Demand $1,513 245
kW-mo/yr
Electricity Fees $1,550 -
Natural Gas $10,537 975
MMBtu
Waste Disposal Costs
Water Usage $368 38
Tgal
Water Disposal $613 38
Tgal
TOTAL YEARLY COSTS $22,269
RECOMMENDED SAVINGS* $5,158 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,095

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $1,233 $216 $1,233
8,805
kWh
-
02 2.7135: Install occupancy sensors $115 $70 $115
820
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,641 $672 $1,641
11,725
kWh
-
04 2.7444: Close holes and openings in building such as broken windows $106 $50 $59
421
kWh
$47
-
MMBtu
05 2.7492: Use proper thickness of insulation on building envelope $2,062 $10,149 - $2,062
-
MMBtu
TOTAL RECOMMENDED $5,158 $11,157 $3,048
21,770
kWh
$2,110
-
MMBtu
TOTAL IMPLEMENTED $3,095 $1,008 $3,048
21,770
kWh
$47
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs