Assessment Year | 2023 |
---|---|
Principal Product | n/a |
NAICS | 444130: Hardware Stores |
SIC | 5251: Hardware Stores |
Sales Range | $5 M to 10M |
# of Employees | 4 |
Plant Area |
23,150
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $7,687 | 66,327 |
kWh
|
$0.12 | |
Electricity Demand | $1,513 | 245 |
kW-mo/yr
|
$6.19 | |
Electricity Fees | $1,550 | - |
|
- | |
Natural Gas | $10,537 | 975 |
MMBtu
|
$10.81 | |
Waste Disposal Costs | |||||
Water Usage | $368 | 38 |
Tgal
|
$9.68 | |
Water Disposal | $613 | 38 |
Tgal
|
$16.14 | |
TOTAL YEARLY COSTS | $22,269 | ||||
RECOMMENDED SAVINGS* | $5,158 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $3,095 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,233 | $216 |
$1,233
8,805
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $115 | $70 |
$115
820
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,641 | $672 |
$1,641
11,725
kWh
|
- | |
04 | 2.7444: Close holes and openings in building such as broken windows | $106 | $50 |
$59
421
kWh
|
$47
-
MMBtu
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $2,062 | $10,149 | - |
$2,062
-
MMBtu
|
|
TOTAL RECOMMENDED | $5,158 | $11,157 |
$3,048
21,770
kWh
|
$2,110
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,095 | $1,008 |
$3,048
21,770
kWh
|
$47
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs