Assessment Year | 2022 |
---|---|
Principal Product | Education |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | less than $500 k |
# of Employees | 80 |
Plant Area |
62,075
ft2
|
Annual Production | 1,500
units
|
Production Hrs. Annual | 1,995
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $4,006 | 23,656 |
kWh
|
$0.17 | |
Natural Gas | $2,060 | 218 |
MMBtu
|
$9.45 | |
Waste Disposal Costs | |||||
Water Usage | $8,530 | 1,421 |
Tgal
|
$6.00 | |
TOTAL YEARLY COSTS | $14,596 | ||||
RECOMMENDED SAVINGS* | $2,787 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,415 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $1,313 | $4,706 | - |
$1,313
-
MMBtu
|
- | |
02 | 2.6232: Install set-back timers | $792 | $428 |
$792
4,688
kWh
|
- | - | |
03 | 3.4151: Minimize water usage | $350 | $102 | - | - |
$350
-
Tgal
|
|
04 | 2.6218: Turn off equipment when not in use | $272 | $1,280 |
$272
1,672
kWh
|
- | - | |
05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $59 | $130 | - |
$59
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $2,787 | $6,646 |
$1,065
6,359
kWh
|
$1,372
-
MMBtu
|
$350
-
Tgal
|
||
TOTAL IMPLEMENTED | $1,415 | $1,810 |
$1,065
6,359
kWh
|
- |
$350
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs