| Assessment Year | 2026 |
|---|---|
| Principal Product | Automotive Exhaust Systems |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 48 |
| Plant Area |
58,000
ft2
|
| Annual Production | 85,000
units
|
| Production Hrs. Annual | 3,100
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $45,531 | 317,286 |
kWh
|
$0.14 | |
| Electricity Fees | $3,547 | - |
|
- | |
| Natural Gas | $17,570 | 2,130 |
MMBtu
|
$8.25 | |
| Other Gas | $330 | 1 |
MMBtu
|
$330.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $279 | 2,531 |
Tgal
|
$0.11 | |
| Water Disposal | $392 | 2,531 |
Tgal
|
$0.15 | |
| TOTAL YEARLY COSTS | $67,649 | ||||
| RECOMMENDED SAVINGS* | $10,975 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,641 | $780 |
$3,641
25,289
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,945 | $16,919 | - |
$2,945
-
MMBtu
|
|
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,664 | $3,218 |
$1,664
11,558
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $356 | $180 |
$356
2,539
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $264 | $250 |
$264
1,833
kWh
|
- | |
| 06 | 2.7221: Lower temperature during the winter season and vice-versa | $112 | - | - |
$112
-
MMBtu
|
|
| 07 | 2.7231: Use radiant heater for spot heating | $1,943 | $8,360 | - |
$1,943
-
MMBtu
|
|
| 08 | 2.7423: Reduce heat gain by window tinting | $50 | $20 |
$50
349
kWh
|
- | |
| TOTAL RECOMMENDED | $10,975 | $29,727 |
$5,975
41,568
kWh
|
$5,000
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs