| Assessment Year | 2026 |
|---|---|
| Principal Product | Automotive interior carpeting |
| NAICS | 314110: Carpet and Rug Mills |
| SIC | 2273: Carpets and Rugs |
| Sales Range | $1 M to 5M |
| # of Employees | 210 |
| Plant Area |
1,850,000
ft2
|
| Annual Production | 3,466,739
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $632,459 | 7,009,822 |
kWh
|
$0.090 | |
| Electricity Demand | $337,597 | 27,911 |
kW-mo/yr
|
$12.10 | |
| Electricity Fees | $96,103 | - |
|
- | |
| Natural Gas | $64,470 | 4,784 |
MMBtu
|
$13.48 | |
| Other Gas | $331 | 1 |
MMBtu
|
$331.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $1 | 1 |
Tgal
|
$1.00 | |
| TOTAL YEARLY COSTS | $1,130,960 | ||||
| RECOMMENDED SAVINGS* | $104,370 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $74,251 | $77,040 | - | - | $74,251 | - | |
| 02 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $9,084 | $9,725 | - | - | - |
$9,084
-
MMBtu
|
|
| 03 | 2.7135: Install occupancy sensors | $206 | $1,222 |
$136
1,059
kWh
|
$70
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,615 | $3,336 |
$2,828
31,357
kWh
|
$786
-
kW-mo/yr
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $205 | $987 |
$173
1,927
kWh
|
$32
-
kW-mo/yr
|
- | - | |
| 06 | 2.7442: Keep doors and windows shut when not on use | $67 | - | - | - | - |
$67
-
MMBtu
|
|
| 07 | 4.821: Pay bills on time to avoid late fees | $16,942 | - | - | - | $16,942 | - | |
| TOTAL RECOMMENDED | $104,370 | $92,310 |
$3,138
34,343
kWh
|
$888
-
kW-mo/yr
|
$91,193 |
$9,151
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||