ITAC Assessment: MU0069
ITAC logo
ITAC Assessment: MU0069
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Automotive Part Trays, Kayaks, Deer Blinds, and Kiddie pools
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 177
Plant Area 270,000
ft2
Annual Production 2,000,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,017,318 22,613,581
kWh
Electricity Demand $339,606 63,789
kW-mo/yr
Electricity Fees $26,849 -
Natural Gas $79,731 12,525
MMBtu
Other Gas $4,371 1
MMBtu
Waste Disposal Costs
Water Usage $59,533 6,241
Tgal
Water Disposal $49,157 6,241
Tgal
TOTAL YEARLY COSTS $2,576,563
RECOMMENDED SAVINGS* $67,910 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $27,682 $5,553 $25,558
287,127
kWh
$2,124
-
kW-mo/yr
02 2.4322: Use or replace with energy efficient substitutes $24,311 $129,488 $22,446
252,207
kWh
$1,865
-
kW-mo/yr
03 2.4221: Install compressor air intakes in coolest locations $4,826 $669 $4,456
50,065
kWh
$370
-
kW-mo/yr
04 2.4231: Reduce the pressure of compressed air to the minimum required $4,011 - $3,703
41,607
kWh
$308
-
kW-mo/yr
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $674 $120 $622
6,991
kWh
$52
-
kW-mo/yr
06 2.6125: Keep equipment clean $3,684 - $3,401
38,215
kWh
$283
-
kW-mo/yr
07 2.7134: Use photocell controls $1,214 $754 $929
10,437
kWh
$285
-
kW-mo/yr
08 2.7134: Use photocell controls $982 - $839
9,427
kWh
$143
-
kW-mo/yr
09 2.7135: Install occupancy sensors $339 $581 $313
3,514
kWh
$26
-
kW-mo/yr
10 2.7291: Reschedule and rearrange multiple-source heating systems $188 $1,500 $143
1,612
kWh
$45
-
kW-mo/yr
TOTAL RECOMMENDED $67,910 $138,665 $62,411
701,201
kWh
$5,499
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs