Assessment Year | 2025 |
---|---|
Principal Product | Automotive Part Trays, Kayaks, Deer Blinds, and Kiddie pools |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 177 |
Plant Area |
270,000
ft2
|
Annual Production | 2,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $2,017,318 | 22,613,581 |
kWh
|
$0.089 | |
Electricity Demand | $339,606 | 63,789 |
kW-mo/yr
|
$5.32 | |
Electricity Fees | $26,849 | - |
|
- | |
Natural Gas | $79,731 | 12,525 |
MMBtu
|
$6.37 | |
Other Gas | $4,371 | 1 |
MMBtu
|
$4,371.10 | |
Waste Disposal Costs | |||||
Water Usage | $59,533 | 6,241 |
Tgal
|
$9.54 | |
Water Disposal | $49,157 | 6,241 |
Tgal
|
$7.88 | |
TOTAL YEARLY COSTS | $2,576,563 | ||||
RECOMMENDED SAVINGS* | $67,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,682 | $5,553 |
$25,558
287,127
kWh
|
$2,124
-
kW-mo/yr
|
|
02 | 2.4322: Use or replace with energy efficient substitutes | $24,311 | $129,488 |
$22,446
252,207
kWh
|
$1,865
-
kW-mo/yr
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $4,826 | $669 |
$4,456
50,065
kWh
|
$370
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,011 | - |
$3,703
41,607
kWh
|
$308
-
kW-mo/yr
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $674 | $120 |
$622
6,991
kWh
|
$52
-
kW-mo/yr
|
|
06 | 2.6125: Keep equipment clean | $3,684 | - |
$3,401
38,215
kWh
|
$283
-
kW-mo/yr
|
|
07 | 2.7134: Use photocell controls | $1,214 | $754 |
$929
10,437
kWh
|
$285
-
kW-mo/yr
|
|
08 | 2.7134: Use photocell controls | $982 | - |
$839
9,427
kWh
|
$143
-
kW-mo/yr
|
|
09 | 2.7135: Install occupancy sensors | $339 | $581 |
$313
3,514
kWh
|
$26
-
kW-mo/yr
|
|
10 | 2.7291: Reschedule and rearrange multiple-source heating systems | $188 | $1,500 |
$143
1,612
kWh
|
$45
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $67,910 | $138,665 |
$62,411
701,201
kWh
|
$5,499
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs