Assessment Year | 2025 |
---|---|
Principal Product | Fabricated Sheet Metal Products |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
150,000
ft2
|
Annual Production | 2,300,000
pieces
|
Production Hrs. Annual | 6,032
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,864 | 4,698,965 |
kWh
|
$0.036 |
Electricity Demand | $320,198 | 9,749 |
kW-mo/yr
|
$32.84 |
Electricity Fees | $31,065 | - |
|
- |
Natural Gas | $25,850 | 18,004 |
MMBtu
|
$1.44 |
Other Gas | $39,895 | 1 |
MMBtu
|
$39,894.79 |
TOTAL YEARLY COSTS | $586,871 | |||
RECOMMENDED SAVINGS* | $115,894 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $226 | - |
$85
2,152
kWh
|
$141
-
kW-mo/yr
|
- | - | |
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $762 | $362 |
$290
7,238
kWh
|
$473
-
kW-mo/yr
|
- | - | |
03 | 2.7134: Use photocell controls | $302 | $550 |
$115
2,870
kWh
|
$188
-
kW-mo/yr
|
- | - | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $49,773 | $560,225 |
$4,794
119,585
kWh
|
$34,138
-
kW-mo/yr
|
$841
-
MMBtu
|
$10,000 | |
05 | 2.7444: Close holes and openings in building such as broken windows | $189 | $627 |
$54
1,351
kWh
|
$61
-
kW-mo/yr
|
$75
-
MMBtu
|
- | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,303 | $4,440 |
$655
16,375
kWh
|
$3,102
-
kW-mo/yr
|
$546
-
MMBtu
|
- | |
07 | 2.7492: Use proper thickness of insulation on building envelope | $251 | $242 |
$37
913
kWh
|
$164
-
kW-mo/yr
|
$50
-
MMBtu
|
- | |
08 | 2.7492: Use proper thickness of insulation on building envelope | $116 | $193 |
$29
720
kWh
|
$47
-
kW-mo/yr
|
$40
-
MMBtu
|
- | |
09 | 2.9114: Use solar heat to make electricty | $59,971 | $561,792 |
$22,774
569,358
kWh
|
$37,197
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $115,894 | $1,128,431 |
$28,832
720,563
kWh
|
$75,510
-
kW-mo/yr
|
$1,552
-
MMBtu
|
$10,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs