| Assessment Year | 1984 |
|---|---|
| Principal Product | EXTRUDED YARN |
| NAICS |
n/a
|
| SIC | 2282: Yarn Texturizing, Throwing, Twisting, and Winding Mills |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $144,210 | 3,963,072 |
kWh
|
$0.036 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,139 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,139 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $5,957 | $15,000 |
$5,957
163,540
kWh
|
|
| 02 | 2.2223: Enhance sensitivity of temperature control and cutoff | $1,493 | $2,000 |
$1,493
41,032
kWh
|
|
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $7,406 | $10,000 |
$7,406
203,400
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,664 | $2,000 |
$1,664
45,721
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $619 | $400 |
$619
16,999
kWh
|
|
| TOTAL RECOMMENDED | $17,139 | $29,400 |
$17,139
470,692
kWh
|
||
| TOTAL IMPLEMENTED | $17,139 | $29,400 |
$17,139
470,692
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs