Assessment Year | 2025 |
---|---|
Principal Product | Elementary School Students |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
45,990
ft2
|
Annual Production | 100
units
|
Production Hrs. Annual | 3,034
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $20,687 | 544,400 |
kWh
|
$0.038 |
Electricity Demand | $19,142 | 1,691 |
kW-mo/yr
|
$11.32 |
TOTAL YEARLY COSTS | $39,829 | |||
RECOMMENDED SAVINGS* | $9,441 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2625: Chill water to the highest temperature possible | $1,394 | $1,000 |
$1,394
36,683
kWh
|
|
02 | 2.7135: Install occupancy sensors | $136 | $1,112 |
$136
3,589
kWh
|
|
03 | 2.9114: Use solar heat to make electricty | $7,485 | $202,800 |
$7,485
196,984
kWh
|
|
04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $426 | $16,427 |
$426
11,213
kWh
|
|
TOTAL RECOMMENDED | $9,441 | $221,339 |
$9,441
248,469
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs