ITAC Assessment: MU0056
ITAC logo
ITAC Assessment: MU0056
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Circuit cards and box builds for military and aerospace components
NAICS 334418: Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 220
Plant Area 100,000
ft2
Annual Production 10,000,000
pieces
Production Hrs. Annual 7,800
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $224,790 2,538,200
kWh
Electricity Demand $124,993 5,824
kW-mo/yr
Electricity Fees $40,829 -
Natural Gas $17,815 1,759
MMBtu
Waste Disposal Costs
Water Usage $22,232 2,831,180
Tgal
TOTAL YEARLY COSTS $430,660
RECOMMENDED SAVINGS* $66,236 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2449: Recover heat from exhausted steam, hot air or hot water $42,634 $3,703 - - $42,634
-
MMBtu
02 2.4221: Install compressor air intakes in coolest locations $601 $1,181 $314
3,487
kWh
$288
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8 - $5
56
kWh
$3
-
kW-mo/yr
-
04 2.7492: Use proper thickness of insulation on building envelope $502 $207 $251
2,794
kWh
$154
-
kW-mo/yr
$97
-
MMBtu
05 2.7491: Insulate glazing, walls, ceilings, and roofs $120 $187 $20
219
kWh
$12
-
kW-mo/yr
$89
-
MMBtu
06 2.7111: Reduce illumination to minimum necessary levels $1,122 - $585
6,505
kWh
$537
-
kW-mo/yr
-
07 2.9114: Use solar heat to make electricty $21,248 $158,400 $15,594
173,267
kWh
$5,654
-
kW-mo/yr
-
TOTAL RECOMMENDED $66,236 $163,678 $16,770
186,328
kWh
$6,647
-
kW-mo/yr
$42,819
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs