Assessment Year | 2024 |
---|---|
Principal Product | Polyethylene Film |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
92,000
ft2
|
Annual Production | 26,280,345
lb
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $663,128 | 9,679,200 |
kWh
|
$0.069 |
Electricity Demand | $238,429 | 16,067 |
kW-mo/yr
|
$14.84 |
Electricity Fees | $10,866 | - |
|
- |
Natural Gas | $73,279 | 8,630 |
MMBtu
|
$8.49 |
Other Gas | $9,300 | 1 |
MMBtu
|
$9,300.01 |
TOTAL YEARLY COSTS | $995,003 | |||
RECOMMENDED SAVINGS* | $109,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $456 | $1,958 |
$244
3,488
kWh
|
$212
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $439 | $51 |
$316
4,511
kWh
|
$123
-
kW-mo/yr
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $1,429 | $4,900 |
$494
7,057
kWh
|
$935
-
kW-mo/yr
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $79,472 | $58,598 |
$61,516
878,804
kWh
|
$17,956
-
kW-mo/yr
|
- | |
05 | 2.7261: Install timers and/or thermostats | $7,196 | $1,904 |
$5,580
79,719
kWh
|
$1,616
-
kW-mo/yr
|
- | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $955 | - |
$698
9,970
kWh
|
$257
-
kW-mo/yr
|
- | |
07 | 2.7124: Make a practice of turning off lights when not needed | $1,119 | - |
$867
12,379
kWh
|
$252
-
kW-mo/yr
|
- | |
08 | 2.7135: Install occupancy sensors | $865 | $512 |
$672
9,605
kWh
|
$193
-
kW-mo/yr
|
- | |
09 | 2.7221: Lower temperature during the winter season and vice-versa | $90 | - |
$64
911
kWh
|
$27
-
kW-mo/yr
|
- | |
10 | 2.7243: Improve air circulation with destratification fans / other methods | $16,560 | $17,565 |
$16,753
622,833
kWh
|
$(-192.9)
-
kW-mo/yr
|
- | |
11 | 2.7261: Install timers and/or thermostats | $473 | $140 |
$366
5,227
kWh
|
$107
-
kW-mo/yr
|
- | |
12 | 2.7492: Use proper thickness of insulation on building envelope | $210 | $546 | - | - |
$210
-
MMBtu
|
|
TOTAL RECOMMENDED | $109,265 | $86,174 |
$87,570
1,634,504
kWh
|
$21,486
-
kW-mo/yr
|
$210
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs