| Assessment Year | 2023 |
|---|---|
| Principal Product | Beer |
| NAICS | 312120: Breweries |
| SIC | 2082: Malt Beverages |
| Sales Range | $1 M to 5M |
| # of Employees | 20 |
| Plant Area |
16,700
ft2
|
| Annual Production | 750
bbl
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,480 | 305,841 |
kWh
|
$0.14 |
| Electricity Fees | $5,926 | - |
|
- |
| Natural Gas | $15,741 | 1,609 |
MMBtu
|
$9.78 |
| TOTAL YEARLY COSTS | $65,146 | |||
| RECOMMENDED SAVINGS* | $13,157 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $166 | - |
$166
1,168
kWh
|
- | |
| 02 | 2.6242: Minimize operation of equipment maintained in standby condition | $37 | - |
$37
264
kWh
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $1,866 | - |
$1,866
13,140
kWh
|
- | |
| 04 | 2.2511: Insulate bare equipment | $2,785 | $5,196 | - |
$2,785
-
MMBtu
|
|
| 05 | 2.7444: Close holes and openings in building such as broken windows | $514 | $1,562 |
$162
1,140
kWh
|
$352
-
MMBtu
|
|
| 06 | 2.2628: Utilize a less expensive cooling method | $6,596 | $22,272 |
$6,596
46,454
kWh
|
- | |
| 07 | 2.9114: Use solar heat to make electricty | $1,193 | $7,618 |
$1,193
8,402
kWh
|
- | |
| TOTAL RECOMMENDED | $13,157 | $36,648 |
$10,021
70,567
kWh
|
$3,137
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs