Assessment Year 2022
Principal Product Remanufactured automobile parts such as fuel injectors
NAICS 336310: Motor Vehicle Gasoline Engine and Engine Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $50
M
to 100
M
# of Employees 90
Plant Area 44,000
ft2
Annual Production 400,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $58,340 1,134,525
kWh
Electricity Demand $87,171 2,557
kW-mo/yr
Electricity Fees $10,043 -
Natural Gas $7,529 938
MMBtu
TOTAL YEARLY COSTS $163,083
RECOMMENDED SAVINGS* $26,461 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,173

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $22,095 $14,729 - - $7,366 - $14,729
02 2.7447: Install vinyl strip / high speed / air curtain doors $2,017 $4,982 - - - $2,017
-
MMBtu
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,374 $360 $581
11,628
kWh
$793
-
kW-mo/yr
- - -
04 2.7111: Reduce illumination to minimum necessary levels $567 - $567
11,340
kWh
- - - -
05 2.7124: Make a practice of turning off lights when not needed $156 - $156
3,110
kWh
- - - -
06 4.821: Pay bills on time to avoid late fees $122 - - - - - $122
07 2.6218: Turn off equipment when not in use $115 - $115
2,304
kWh
- - - -
08 2.7135: Install occupancy sensors $15 $39 $15
304
kWh
- - - -
TOTAL RECOMMENDED $26,461 $20,110 $1,434
28,686
kWh
$793
-
kW-mo/yr
$7,366 $2,017
-
MMBtu
$14,851
TOTAL IMPLEMENTED $24,173 $15,128 $1,163
23,272
kWh
$793
-
kW-mo/yr
$7,366 - $14,851
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs