| Assessment Year | 2026 |
|---|---|
| Principal Product | Vehicle seat frames, seat cushions, interior door panels, arm rests |
| NAICS | 336360: Motor Vehicle Seating and Interior Trim Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $100 M to 500M |
| # of Employees | 328 |
| Plant Area |
420,000
ft2
|
| Annual Production | 177,336
units
|
| Production Hrs. Annual | 6,456
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $849,789 | 9,955,200 |
kWh
|
$0.085 | |
| Electricity Demand | $337,313 | 21,869 |
kW-mo/yr
|
$15.42 | |
| Electricity Fees | $5,808 | - |
|
- | |
| Natural Gas | $34,162 | 2,455 |
MMBtu
|
$13.92 | |
| Waste Disposal Costs | |||||
| Water Usage | $9,630 | 1,877 |
Tgal
|
$5.13 | |
| Water Disposal | $9,630 | 1,871 |
Tgal
|
$5.15 | |
| TOTAL YEARLY COSTS | $1,246,332 | ||||
| RECOMMENDED SAVINGS* | $165,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,850 | $16,500 |
$1,850
21,760
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,606 | $4,076 |
$5,606
65,950
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $12,942 | $7,943 |
$12,942
152,263
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $7,543 | $4,022 |
$7,543
88,738
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,275 | $18,599 |
$14,545
171,119
kWh
|
$730
-
kW-mo/yr
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,167 | $1,153 |
$1,167
13,728
kWh
|
- | |
| 07 | 2.8117: Install sub-metering equipment | $98,081 | $934 |
$81,219
955,520
kWh
|
$16,862
-
kW-mo/yr
|
|
| 08 | 2.6218: Turn off equipment when not in use | $17,316 | - |
$17,316
203,716
kWh
|
- | |
| 09 | 2.6125: Keep equipment clean | $5,606 | - |
$5,606
65,950
kWh
|
- | |
| TOTAL RECOMMENDED | $165,386 | $53,227 |
$147,794
1,738,744
kWh
|
$17,592
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs