| Assessment Year | 2026 |
|---|---|
| Principal Product | Sofa Sleeper Mechanisms & Mattresses |
| NAICS | 337215: Showcase, Partition, Shelving, and Locker Manufacturing |
| SIC | 3429: Hardware, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 55 |
| Plant Area |
203,025
ft2
|
| Annual Production | 348,275
units
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $85,250 | 776,670 |
kWh
|
$0.11 | |
| Electricity Demand | $25,725 | 3,788 |
kW-mo/yr
|
$6.79 | |
| Electricity Fees | $5,269 | - |
|
- | |
| Natural Gas | $41,134 | 3,017 |
MMBtu
|
$13.63 | |
| Waste Disposal Costs | |||||
| Water Usage | $599 | 200 |
Tgal
|
$3.00 | |
| Water Disposal | $599 | 200 |
Tgal
|
$3.00 | |
| TOTAL YEARLY COSTS | $158,576 | ||||
| RECOMMENDED SAVINGS* | $70,476 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $408 | $2,243 |
$408
3,716
kWh
|
- | - | |
| 02 | 4.132: Purchase new equipment to reduce material use / cost | $398 | $1,280 |
$398
3,627
kWh
|
- | - | |
| 03 | 2.7442: Keep doors and windows shut when not on use | $39,664 | $104,260 | - | - |
$39,664
-
MMBtu
|
|
| 04 | 2.7291: Reschedule and rearrange multiple-source heating systems | $14,437 | - | - | - |
$14,437
-
MMBtu
|
|
| 05 | 2.7221: Lower temperature during the winter season and vice-versa | $4,474 | - |
$4,474
40,748
kWh
|
- | - | |
| 06 | 2.7425: Clean or color roof to reduce solar load | $4,092 | $42,669 |
$4,092
37,280
kWh
|
- | - | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $7,003 | - | - | $7,003 | - | |
| TOTAL RECOMMENDED | $70,476 | $150,452 |
$9,372
85,371
kWh
|
$7,003 |
$54,101
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs