ITAC Assessment: MS0461
ITAC logo
ITAC Assessment: MS0461
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Custom Tools
NAICS 333514: Special Die and Tool, Die Set, Jig, and Fixture Manufacturing
SIC 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds
Sales Range $5
M
to 10
M
# of Employees 50
Plant Area 40,000
ft2
Annual Production 10,000
units
Production Hrs. Annual 2,184
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,392 972,200
kWh
Electricity Demand $45,131 3,579
kW-mo/yr
Natural Gas $3,762 388
MMBtu
LPG $5,797 179
MMBtu
Waste Disposal Costs
Water Usage $4,698 1,566
Tgal
Water Disposal $3,638 1,566
Tgal
TOTAL YEARLY COSTS $148,418
RECOMMENDED SAVINGS* $99,817 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings One-time Revenue or Avoided Cost Savings Primary Product Savings
01 4.513: Re-arrange equipment layout to reduce labor costs $4,800 $2,500 - - - - $4,800
02 2.7135: Install occupancy sensors $184 $2,514 $184
2,091
kWh
- - - -
03 4.311: Schedule deliveries according to demand $50,000 $318,000 - - - - $50,000
04 2.1321: Replace fossil fuel equipment with electrical equipment $4,769 $50,000 $(-1,028.0)
(-11,712)
kWh
- $5,797
-
MMBtu
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $1,305 - $1,305
14,859
kWh
- - - -
06 2.7221: Lower temperature during the winter season and vice-versa $3,769 - $3,769
42,930
kWh
- - - -
07 2.6218: Turn off equipment when not in use $5,284 - $5,284
61,150
kWh
- - - -
08 2.7261: Install timers and/or thermostats $15,624 $1,339 $15,624
177,954
kWh
- - - -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $4,862 $20,295 $2,744
31,247
kWh
$2,118
-
kW-mo/yr
- - -
10 2.8121: Apply for tax-free status for energy purchases $9,220 - - - - $9,220 -
TOTAL RECOMMENDED $99,817 $394,648 $27,882
318,520
kWh
$2,118
-
kW-mo/yr
$5,797
-
MMBtu
$9,220 $54,800
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings One-time Revenue or Avoided Cost Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs