Assessment Year | 2025 |
---|---|
Principal Product | Step Drill Bits |
NAICS | 333120: Construction Machinery Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $50 M to 100M |
# of Employees | 236 |
Plant Area |
150,000
ft2
|
Annual Production | 10,600,000
units
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $785,544 | 10,170,468 |
kWh
|
$0.077 | |
Electricity Demand | $110,992 | 19,459 |
kW-mo/yr
|
$5.70 | |
Electricity Fees | $(-10,027.2) | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $18,747 | 106,618 |
Tgal
|
$0.18 | |
TOTAL YEARLY COSTS | $905,255 | ||||
RECOMMENDED SAVINGS* | $2,420,087 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.231: Purchase equipment instead of leasing | $85,200 | $140,028 | - | - | - | $85,200 | - | |
02 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $11,257 | $1,712 |
$11,257
146,200
kWh
|
- | - | - | - | |
03 | 3.4159: Replace treated water with well / surface water | $18,747 | $64,200 | - | - |
$18,747
-
Tgal
|
- | - | |
04 | 4.111: Add equipment/ operators to reduce production bottleneck | $2,292,500 | $1,179,452 | - | - | - | - | $2,292,500 | |
05 | 2.2531: Re-size charging openings or add movable cover or door | $12,383 | - |
$11,902
154,574
kWh
|
$481
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $2,420,087 | $1,385,392 |
$23,159
300,774
kWh
|
$481
-
kW-mo/yr
|
$18,747
-
Tgal
|
$85,200 | $2,292,500 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs