| Assessment Year | 2025 |
|---|---|
| Principal Product | Steel Beams |
| NAICS | 331221: Rolled Steel Shape Manufacturing |
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $50 M to 100M |
| # of Employees | 142 |
| Plant Area |
80,000
ft2
|
| Annual Production | 29,400
ton
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $565,585 | 3,637,264 |
kWh
|
$0.16 | |
| Electricity Demand | $299,464 | 20,471 |
kW-mo/yr
|
$14.63 | |
| Natural Gas | $344,108 | 144,425 |
MMBtu
|
$2.38 | |
| Waste Disposal Costs | |||||
| Water Usage | $16,574 | 5,553 |
Tgal
|
$2.98 | |
| Water Disposal | $443 | 5,553 |
Tgal
|
$0.080 | |
| TOTAL YEARLY COSTS | $1,226,174 | ||||
| RECOMMENDED SAVINGS* | $2,522,974 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.231: Purchase equipment instead of leasing | $138,378 | $120,000 | - | - |
$6,378
-
MMBtu
|
$132,000 | - | |
| 02 | 4.651: Install back-up equipment | $16,920 | $3,906 | - | - | - | - | $16,920 | |
| 03 | 4.446: Automate finishing process | $174,531 | $413,494 |
$174,531
1,126,007
kWh
|
- | - | - | - | |
| 04 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $7,830 | $5,644 |
$7,830
50,518
kWh
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,095 | $1,190 |
$1,058
6,825
kWh
|
$37
-
kW-mo/yr
|
- | - | - | |
| 06 | 3.1191: Change procedures / equipment / operating conditions | $2,184,220 | $60,000 | - | - | - | - | $2,184,220 | |
| TOTAL RECOMMENDED | $2,522,974 | $604,234 |
$183,419
1,183,350
kWh
|
$37
-
kW-mo/yr
|
$6,378
-
MMBtu
|
$132,000 | $2,201,140 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs