Assessment Year | 2025 |
---|---|
Principal Product | Steel Beams |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
Sales Range | $50 M to 100M |
# of Employees | 142 |
Plant Area |
80,000
ft2
|
Annual Production | 294,000
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $565,585 | 3,637,264 |
kWh
|
$0.16 | |
Electricity Demand | $299,464 | 20,471 |
kW-mo/yr
|
$14.63 | |
Natural Gas | $344,108 | 144,425 |
MMBtu
|
$2.38 | |
Waste Disposal Costs | |||||
Water Usage | $16,574 | 5,553 |
Tgal
|
$2.98 | |
Water Disposal | $443 | 5,553 |
Tgal
|
$0.080 | |
TOTAL YEARLY COSTS | $1,226,174 | ||||
RECOMMENDED SAVINGS* | $2,609,196 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.231: Purchase equipment instead of leasing | $138,378 | $120,000 | - | - |
$6,378
-
MMBtu
|
$132,000 | - | |
02 | 4.651: Install back-up equipment | $16,920 | $3,906 | - | - | - | - | $16,920 | |
03 | 4.446: Automate finishing process | $260,753 | $413,494 |
$(-9,246.7)
(-59,656)
kWh
|
- | - | $270,000 | - | |
04 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $7,830 | $5,644 |
$7,830
50,518
kWh
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,095 | $1,190 |
$1,058
6,825
kWh
|
$37
-
kW-mo/yr
|
- | - | - | |
06 | 3.1191: Change procedures / equipment / operating conditions | $2,184,220 | $60,000 | - | - | - | - | $2,184,220 | |
TOTAL RECOMMENDED | $2,609,196 | $604,234 |
$(-358.7)
(-2,313)
kWh
|
$37
-
kW-mo/yr
|
$6,378
-
MMBtu
|
$402,000 | $2,201,140 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |