| Assessment Year | 2024 |
|---|---|
| Principal Product | Vacuum Trucks |
| NAICS | 332420: Metal Tank (Heavy Gauge) Manufacturing |
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $10 M to 50M |
| # of Employees | 132 |
| Plant Area |
150,000
ft2
|
| Annual Production | 227
units
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $116,988 | 989,094 |
kWh
|
$0.12 | |
| Electricity Fees | $10,877 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $1,434 | 415 |
Tgal
|
$3.46 | |
| TOTAL YEARLY COSTS | $129,299 | ||||
| RECOMMENDED SAVINGS* | $63,042 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7232: Replace existing hvac unit with high efficiency model | $399 | $4,320 |
$399
3,327
kWh
|
|
| 02 | 2.4226: Use / purchase optimum sized compressor | $5,546 | $29,394 |
$5,546
46,218
kWh
|
|
| 03 | 2.9114: Use solar heat to make electricty | $57,097 | $340,025 |
$57,097
475,812
kWh
|
|
| TOTAL RECOMMENDED | $63,042 | $373,739 |
$63,042
525,356
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs