| Assessment Year | 2023 |
|---|---|
| Principal Product | Automotive Body Structure |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
310,000
ft2
|
| Annual Production | 6,000,496
pieces
|
| Production Hrs. Annual | 4,290
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $787,709 | 10,940,400 |
kWh
|
$0.072 | |
| Electricity Demand | $277,380 | 27,738 |
kW-mo/yr
|
$10.00 | |
| Electricity Fees | $74,743 | - |
|
- | |
| Natural Gas | $10,887 | 798 |
MMBtu
|
$13.63 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,364 | 11,301 |
Tgal
|
$0.12 | |
| TOTAL YEARLY COSTS | $1,152,082 | ||||
| RECOMMENDED SAVINGS* | $216,320 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,886 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $1,912 | $3,171 |
$1,912
27,317
kWh
|
|
| 02 | 2.7446: Utilize sensors controlling roof and wall openings | $2,264 | $21,500 |
$2,264
31,445
kWh
|
|
| 03 | 2.4239: Eliminate or reduce compressed air usage | $1,886 | $2,761 |
$1,886
26,197
kWh
|
|
| 04 | 2.9114: Use solar heat to make electricty | $210,258 | $2,164,995 |
$210,258
2,920,250
kWh
|
|
| TOTAL RECOMMENDED | $216,320 | $2,192,427 |
$216,320
3,005,209
kWh
|
||
| TOTAL IMPLEMENTED | $1,886 | $2,761 |
$1,886
26,197
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs