Assessment Year | 2011 |
---|---|
Principal Product | composite jet engine parts |
NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $100 M to 500M |
# of Employees | 400 |
Plant Area |
330,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $598,849 | 11,858,400 |
kWh
|
$0.050 |
Electricity Demand | $368,322 | 24,154 |
kW-mo/yr
|
$15.25 |
Electricity Fees | $11,310 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,822 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $6,041 | $1,900 |
$4,214
83,444
kWh
|
$1,738
-
kW-mo/yr
|
$89 | |
02 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $3,680 | $611 |
$3,626
71,818
kWh
|
- | $54 | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $7,101 | $13,781 |
$6,996
138,527
kWh
|
- | $105 | |
TOTAL RECOMMENDED | $16,822 | $16,292 |
$14,836
293,789
kWh
|
$1,738
-
kW-mo/yr
|
$248 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs