| Assessment Year | 1995 |
|---|---|
| Principal Product | Seamless Rolled Rings |
| NAICS |
n/a
|
| SIC | 3463: Nonferrous Forgings |
| Sales Range | $10 M to 50M |
| # of Employees | 121 |
| Plant Area |
120,000
ft2
|
| Annual Production | 25,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $602,263 | 7,780,188 |
kWh
|
$0.077 |
| Natural Gas | $460,350 | 107,024 |
MMBtu
|
$4.30 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $133,767 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,318 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8123: Pay utility bills on time | $5,674 | - |
$5,674
-
kWh
|
- | |
| 02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $90,007 | $29,278 | - |
$90,007
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,176 | $717 |
$2,176
28,136
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $33,664 | $21,633 |
$33,664
434,936
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $644 | $300 |
$644
8,499
kWh
|
- | |
| 06 | 2.3212: Optimize plant power factor | $1,602 | $5,472 |
$1,602
-
kWh
|
- | |
| TOTAL RECOMMENDED | $133,767 | $57,400 |
$43,760
471,571
kWh
|
$90,007
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,318 | $300 |
$6,318
8,499
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs