Assessment Year | 2011 |
---|---|
Principal Product | Heat Exchanger Units |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $100 M to 500M |
# of Employees | 800 |
Plant Area |
1,000,000
ft2
|
Annual Production | 90,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $718,297 | 17,291,736 |
kWh
|
$0.042 |
Electricity Demand | $126,194 | 34,167 |
kW-mo/yr
|
$3.69 |
Electricity Fees | $290,222 | - |
|
- |
Natural Gas | $320,321 | 60,766 |
MMBtu
|
$5.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $117,843 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,919 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $76,988 | $223,560 |
$52,910
1,273,709
kWh
|
$7,431
-
kW-mo/yr
|
$16,647 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,473 | $142 |
$12,119
291,749
kWh
|
- | $3,354 | |
03 | 2.7124: Make a practice of turning off lights when not needed | $14,805 | - |
$7,331
176,472
kWh
|
$4,116
-
kW-mo/yr
|
$3,358 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,932 | $480 |
$4,635
111,587
kWh
|
- | $1,297 | |
05 | 2.4221: Install compressor air intakes in coolest locations | $2,936 | $1,056 |
$1,552
37,355
kWh
|
$718
-
kW-mo/yr
|
$666 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,709 | $17,527 |
$1,037
24,956
kWh
|
$284
-
kW-mo/yr
|
$388 | |
TOTAL RECOMMENDED | $117,843 | $242,765 |
$79,584
1,915,828
kWh
|
$12,549
-
kW-mo/yr
|
$25,710 | ||
TOTAL IMPLEMENTED | $37,919 | $18,149 |
$25,122
604,764
kWh
|
$4,400
-
kW-mo/yr
|
$8,397 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs