| Assessment Year | 2010 |
|---|---|
| Principal Product | PLASTIC BAGS |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
75,000
ft2
|
| Annual Production | 11,000
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $290,541 | 7,148,400 |
kWh
|
$0.041 |
| Electricity Demand | $50,654 | 12,584 |
kW-mo/yr
|
$4.03 |
| Electricity Fees | $83,044 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $41,283 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $24,993 | $19,250 |
$23,600
660,000
kWh
|
$263
-
kW-mo/yr
|
$1,130 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,215 | $14,101 |
$8,073
225,756
kWh
|
$1,082
-
kW-mo/yr
|
$60 | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $3,623 | $4,140 |
$3,418
95,574
kWh
|
- | $205 | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,080 | $418 |
$2,947
82,408
kWh
|
- | $133 | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $372 | $119 |
$351
9,829
kWh
|
- | $21 | |
| TOTAL RECOMMENDED | $41,283 | $38,028 |
$38,389
1,073,567
kWh
|
$1,345
-
kW-mo/yr
|
$1,549 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs