Assessment Year 2010
Principal Product PLASTIC BAGS
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 75,000
ft2
Annual Production 11,000
ton
Production Hrs. Annual 8,760
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $290,541 7,148,400
kWh
Electricity Demand $50,654 12,584
kW-mo/yr
Electricity Fees $83,044 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $41,283 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.4133: Use most efficient type of electric motors $24,993 $19,250 $23,600
660,000
kWh
$263
-
kW-mo/yr
$1,130
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,215 $14,101 $8,073
225,756
kWh
$1,082
-
kW-mo/yr
$60
03 2.4226: Use / purchase optimum sized compressor $3,623 $4,140 $3,418
95,574
kWh
- $205
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,080 $418 $2,947
82,408
kWh
- $133
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $372 $119 $351
9,829
kWh
- $21
TOTAL RECOMMENDED $41,283 $38,028 $38,389
1,073,567
kWh
$1,345
-
kW-mo/yr
$1,549
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs