Assessment Year 2006
Principal Product vinyl
NAICS 313310: Textile and Fabric Finishing Mills
SIC 2295: Coated Fabrics, Not Rubberized
Sales Range $100
M
to 500
M
# of Employees 375
Plant Area 700,000
ft2
Annual Production 300,000,000
units
Production Hrs. Annual 7,488
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,140,801 36,017,600
kWh
Electricity Demand $704,150 72,701
kW-mo/yr
Electricity Fees $30,374 -
Natural Gas $1,572,843 171,573
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $59,124 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $58,110

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $24,158 $36,274 $19,314
505,597
kWh
$8,537
-
kW-mo/yr
$(-3,693.0) -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $21,061 $87,943 $16,124
422,088
kWh
$8,169
-
kW-mo/yr
$(-3,232.0) -
03 2.2135: Repair and eliminate steam leaks $6,813 $37 - - - $6,813
-
MMBtu
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,542 $3,825 $2,581
67,555
kWh
$1,507
-
kW-mo/yr
$(-546.0) -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,141 $223 $2,457
64,315
kWh
- $(-316.0) -
06 2.4221: Install compressor air intakes in coolest locations $1,014 $410 $717
18,769
kWh
$453
-
kW-mo/yr
$(-156.0) -
07 2.2136: Install / repair insulation on steam lines $395 $48 - - - $395
-
MMBtu
TOTAL RECOMMENDED $59,124 $128,760 $41,193
1,078,324
kWh
$18,666
-
kW-mo/yr
$(-7,943.0) $7,208
-
MMBtu
TOTAL IMPLEMENTED $58,110 $128,350 $40,476
1,059,555
kWh
$18,213
-
kW-mo/yr
$(-7,787.0) $7,208
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs