Assessment Year 2005
Principal Product Veneer
NAICS 321211: Hardwood Veneer and Plywood Manufacturing
SIC 2435: Hardwood Veneer and Plywood
Sales Range $10
M
to 50
M
# of Employees 70
Plant Area 232,000
ft2
Annual Production 5,700
thousand feet
Production Hrs. Annual 6,240
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $147,982 3,318,084
kWh
Electricity Demand $34,329 10,654
kW-mo/yr
Electricity Fees $66,024 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $244,736 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Ancillary Material Cost Savings
01 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat $219,363 $472,500 $311,155
6,991,920
kWh
$32,934
-
kW-mo/yr
$114,474 $(-239,200.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,947 $22,298 $7,245
169,126
kWh
$1,038
-
kW-mo/yr
$2,664 -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,573 $11,233 $4,188
97,775
kWh
$802
-
kW-mo/yr
$1,583 -
04 2.4133: Use most efficient type of electric motors $2,467 $4,140 $1,543
36,027
kWh
$332
-
kW-mo/yr
$592 -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,337 $7,721 $1,545
36,060
kWh
$224
-
kW-mo/yr
$568 -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,990 $203 $1,488
34,739
kWh
- $502 -
07 2.7261: Install timers and/or thermostats $1,059 $236 $792
18,498
kWh
- $267 -
TOTAL RECOMMENDED $244,736 $518,331 $327,956
7,384,145
kWh
$35,330
-
kW-mo/yr
$120,650 $(-239,200.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs