Assessment Year | 1993 |
---|---|
Principal Product | Women's Jeans and Shorts |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $10 M to 50M |
# of Employees | 360 |
Plant Area |
48,000
ft2
|
Annual Production | 2,300,000
pieces
|
Production Hrs. Annual | 3,910
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,126 | 2,289,566 |
kWh
|
$0.047 |
LPG | $46,175 | 9,939 |
MMBtu
|
$4.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,865 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $359 | $995 | - |
$359
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,046 | $8,033 |
$1,046
22,274
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $256 | $105 |
$256
5,569
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,969 | $5,991 |
$1,969
42,204
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,842 | $778 |
$1,842
39,273
kWh
|
- | |
06 | 2.7442: Keep doors and windows shut when not on use | $673 | $745 | - |
$673
-
MMBtu
|
|
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $7,720 | $276 |
$2,302
49,238
kWh
|
$5,418
-
MMBtu
|
|
TOTAL RECOMMENDED | $13,865 | $16,923 |
$7,415
158,558
kWh
|
$6,450
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs