Assessment Year | 2005 |
---|---|
Principal Product | school uniforms |
NAICS | 313310: Textile and Fabric Finishing Mills |
SIC | 2253: Knit Outerwear Mills |
Sales Range | $10 M to 50M |
# of Employees | 315 |
Plant Area |
157,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 4,700
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,145 | 2,263,400 |
kWh
|
$0.033 |
Electricity Demand | $66,473 | 10,148 |
kW-mo/yr
|
$6.55 |
Electricity Fees | $18,730 | - |
|
- |
Natural Gas | $52,417 | 5,909 |
MMBtu
|
$8.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,785 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,600 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.522: Modify storage space to avoid rental of a warehouse | $60,336 | $15,000 | - | - | - | - | $60,336 | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $1,425 | $3,780 | - | - | - |
$1,425
-
MMBtu
|
- | |
03 | 2.8123: Pay utility bills on time | $783 | - | - | - | - | - | $783 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $569 | $151 |
$571
22,103
kWh
|
- | $(-2.0) | - | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $424 | $1,495 |
$426
16,466
kWh
|
- | $(-2.0) | - | - | |
06 | 2.7122: Disconnect ballasts | $153 | $216 |
$89
3,452
kWh
|
$59
-
kW-mo/yr
|
$5 | - | - | |
07 | 2.2135: Repair and eliminate steam leaks | $95 | $19 | - | - | - |
$95
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $63,785 | $20,661 |
$1,086
42,021
kWh
|
$59
-
kW-mo/yr
|
$1 |
$1,520
-
MMBtu
|
$61,119 | ||
TOTAL IMPLEMENTED | $1,600 | $386 |
$660
25,555
kWh
|
$59
-
kW-mo/yr
|
$3 |
$95
-
MMBtu
|
$783 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs