Assessment Year | 2004 |
---|---|
Principal Product | Margarine |
NAICS | 311225: Fats and Oils Refining and Blending |
SIC | 2079: Shortening, Table Oils, Margarine, and Other Edible Fats and Oils, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 325 |
Plant Area |
242,000
ft2
|
Annual Production | 250,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $312,116 | 15,891,000 |
kWh
|
$0.020 |
Electricity Demand | $193,916 | 40,521 |
kW-mo/yr
|
$4.79 |
Electricity Fees | $283,791 | - |
|
- |
Natural Gas | $455,159 | 80,520 |
MMBtu
|
$5.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,804 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $42,481 | $15,060 | - | - | - |
$42,481
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,381 | $33,730 |
$9,226
314,031
kWh
|
$3,280
-
kW-mo/yr
|
$875 | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,987 | $21,549 |
$12,137
413,127
kWh
|
- | $850 | - | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $10,524 | $11,556 |
$9,835
334,777
kWh
|
- | $689 | - | - | |
05 | 2.2134: Eliminate leaks in high pressure reducing stations | $10,281 | $73 | - | - | - |
$10,281
-
MMBtu
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,886 | $4,350 |
$3,590
122,195
kWh
|
$1,911
-
kW-mo/yr
|
$385 | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,314 | $322 |
$2,163
73,610
kWh
|
- | $151 | - | - | |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $1,950 | $1,000 | - | - | - | - | $1,950 | |
TOTAL RECOMMENDED | $99,804 | $87,640 |
$36,951
1,257,740
kWh
|
$5,191
-
kW-mo/yr
|
$2,950 |
$52,762
-
MMBtu
|
$1,950 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs