ITAC Assessment: MS0257
ITAC logo
ITAC Assessment: MS0257
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Cottonseed Oil
NAICS 311224: Soybean and Other Oilseed Processing
SIC 2074: Cottonseed Oil Mills
Sales Range $50
M
to 100
M
# of Employees 92
Plant Area 1,000,000
ft2
Annual Production 280,000
ton
Production Hrs. Annual 8,064
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,411,815 28,039,200
kWh
Electricity Demand $166,001 65,895
kW-mo/yr
Electricity Fees $54,244 -
Natural Gas $1,173,701 182,521
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $220,501 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $126,540

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $71,237 $88,344 $63,496
1,266,636
kWh
$4,658
-
kW-mo/yr
$3,083 -
02 2.1233: Analyze flue gas for proper air/fuel ratio $67,341 $2,000 - - - $67,341
-
MMBtu
03 2.2135: Repair and eliminate steam leaks $36,924 $54 - - - $36,924
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $15,889 $17,026 n/a $14,165
282,564
kWh
$1,037
-
kW-mo/yr
$687 -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $15,325 $348 $14,527
289,796
kWh
- $798 -
06 2.7132: Install timers on light switches in little used areas $6,318 $2,673 $5,989
119,477
kWh
- $329 -
07 2.2515: Use optimum thickness insulation $3,906 $1,356 - - - $3,906
-
MMBtu
08 2.4239: Eliminate or reduce compressed air usage $1,163 $742 $1,103
21,998
kWh
- $60 -
09 2.4221: Install compressor air intakes in coolest locations $1,231 $255 $1,094
21,828
kWh
$84
-
kW-mo/yr
$53 -
10 2.2136: Install / repair insulation on steam lines $632 $1,029 - - - $632
-
MMBtu
11 2.7142: Utilize higher efficiency lamps and/or ballasts $535 $969 $477
9,513
kWh
$35
-
kW-mo/yr
$23 -
TOTAL RECOMMENDED $220,501 $114,796 $100,851
2,011,812
kWh
$5,814
-
kW-mo/yr
$5,033 $108,803
-
MMBtu
TOTAL IMPLEMENTED $126,540 $6,104 $20,516
409,273
kWh
- $1,127 $104,897
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs