Assessment Year | 2024 |
---|---|
Principal Product | Metal heat treating |
NAICS | 332811: Metal Heat Treating |
SIC | 3398: Metal Heat Treating |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
75,600
ft2
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 6,624
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $215,273 | 4,535,352 |
kWh
|
$0.047 |
Electricity Demand | $201,431 | 16,803 |
kW-mo/yr
|
$11.99 |
Electricity Fees | $13,288 | - |
|
- |
Natural Gas | $703,797 | 100,210 |
MMBtu
|
$7.02 |
TOTAL YEARLY COSTS | $1,133,789 | |||
RECOMMENDED SAVINGS* | $45,735 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $40,720 | $77,840 | - |
$40,720
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,190 | $2,260 |
$1,350
28,670
kWh
|
$780
-
kW-mo/yr
|
$60 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,515 | - |
$1,020
21,640
kWh
|
$495
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,310 | - |
$1,310
27,920
kWh
|
- | - | |
TOTAL RECOMMENDED | $45,735 | $80,100 |
$3,680
78,230
kWh
|
$41,995
-
kW-mo/yr
|
$60 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs