Assessment Year | 2004 |
---|---|
Principal Product | Belt Conveyor Idlers |
NAICS | 333922: Conveyor and Conveying Equipment Manufacturing |
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 63 |
Plant Area |
146,232
ft2
|
Annual Production | 9,000,000
lb
|
Production Hrs. Annual | 1,920
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $70,789 | 1,180,200 |
kWh
|
$0.060 |
Electricity Demand | $13,269 | 6,349 |
kW-mo/yr
|
$2.09 |
Electricity Fees | $1,309 | - |
|
- |
Natural Gas | $30,793 | 6,349 |
MMBtu
|
$4.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,777 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,577 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,032 | $11 |
$3,213
58,109
kWh
|
$759
-
kW-mo/yr
|
$60 | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,649 | $4,689 |
$1,316
23,792
kWh
|
$309
-
kW-mo/yr
|
$24 | - | - | - | - | |
03 | 2.7231: Use radiant heater for spot heating | $1,526 | $4,000 | - | - | - |
$1,526
-
MMBtu
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $853 | $288 |
$840
15,184
kWh
|
- | $13 | - | - | - | - | |
05 | 3.6124: Burn waste oil for heat | $703 | $2,190 | - | - | - |
$303
-
MMBtu
|
$400
-
gal
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $480 | $708 |
$473
8,548
kWh
|
- | $7 | - | - | - | - | |
07 | 3.1193: Convert from batch operation to continuous processing | $336 | $68 | - | - | - | - | - |
$224
-
lb
|
$112 | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $198 | $735 |
$157
2,840
kWh
|
$38
-
kW-mo/yr
|
$3 | - | - | - | - | |
TOTAL RECOMMENDED | $9,777 | $12,689 |
$5,999
108,473
kWh
|
$1,106
-
kW-mo/yr
|
$107 |
$1,829
-
MMBtu
|
$400
-
gal
|
$224
-
lb
|
$112 | ||
TOTAL IMPLEMENTED | $2,577 | $5,023 |
$997
18,024
kWh
|
$38
-
kW-mo/yr
|
$16 |
$1,526
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs