Assessment Year | 2004 |
---|---|
Principal Product | Plastic Bags |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
68,000
ft2
|
Annual Production | 13,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $171,040 | 4,361,880 |
kWh
|
$0.039 |
Electricity Demand | $28,226 | 6,176 |
kW-mo/yr
|
$4.57 |
Electricity Fees | $51,711 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,539 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,405 | $9,114 |
$5,515
165,451
kWh
|
$791
-
kW-mo/yr
|
$2,099 | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,198 | $2,253 |
$3,410
102,307
kWh
|
$490
-
kW-mo/yr
|
$1,298 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,222 | $258 |
$2,387
71,601
kWh
|
- | $835 | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $1,826 | $81 |
$1,198
35,951
kWh
|
$172
-
kW-mo/yr
|
$456 | |
05 | 2.7229: Air condition only space necessary | $1,335 | $600 |
$581
17,420
kWh
|
$455
-
kW-mo/yr
|
$299 | |
06 | 2.4133: Use most efficient type of electric motors | $1,169 | $3,310 |
$866
25,972
kWh
|
- | $303 | |
07 | 2.7261: Install timers and/or thermostats | $553 | $472 |
$410
12,287
kWh
|
- | $143 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $427 | $901 |
$279
8,361
kWh
|
$42
-
kW-mo/yr
|
$106 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $404 | $1,038 |
$265
7,940
kWh
|
$39
-
kW-mo/yr
|
$100 | |
TOTAL RECOMMENDED | $22,539 | $18,027 |
$14,911
447,290
kWh
|
$1,989
-
kW-mo/yr
|
$5,639 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs