Assessment Year 2004
Principal Product Shower Curtains
NAICS 314120: Curtain and Linen Mills
SIC 2391: Curtains and Draperies
Sales Range $100
M
to 500
M
# of Employees 380
Plant Area 450,000
ft2
Annual Production 5,000,000
pieces
Production Hrs. Annual 5,824
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $397,171 8,844,040
kWh
Electricity Demand $69,650 21,602
kW-mo/yr
Electricity Fees $96,175 -
Natural Gas $62,305 8,007
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $102,982 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,275

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
01 2.7124: Make a practice of turning off lights when not needed $42,786 $4,860 $34,598
839,961
kWh
- $8,188 -
02 2.8112: Combine utility meters $30,379 $200 - - $30,379 -
03 2.7241: Install outside air damper / economizer on hvac unit $12,381 $1,000 $10,011
243,055
kWh
- $2,370 -
04 2.7261: Install timers and/or thermostats $5,138 $1,000 $4,155
100,865
kWh
- $983 -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,485 $247 $3,626
88,039
kWh
- $859 -
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $3,141 - - $2,534
-
kW-mo/yr
$607 -
07 2.3132: Recharge batteries on during off-peak demand periods $3,004 - - $2,420
-
kW-mo/yr
$584 -
08 2.7229: Air condition only space necessary $1,009 $400 $538
13,075
kWh
$276
-
kW-mo/yr
$195 -
09 4.821: Pay bills on time to avoid late fees $659 $100 - - - $659
TOTAL RECOMMENDED $102,982 $7,807 $52,928
1,284,995
kWh
$5,230
-
kW-mo/yr
$44,165 $659
TOTAL IMPLEMENTED $50,275 $5,107 $38,224
928,000
kWh
$2,420
-
kW-mo/yr
$9,631 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs