Assessment Year | 2003 |
---|---|
Principal Product | Rubber Industrial Tires |
NAICS | 326211: Tire Manufacturing (except Retreading) |
SIC | 3011: Tires and Inner Tubes |
Sales Range | $5 M to 10M |
# of Employees | 26 |
Plant Area |
110,000
ft2
|
Annual Production | 80,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $33,187 | 711,640 |
kWh
|
$0.047 |
Electricity Demand | $21,871 | 2,768 |
kW-mo/yr
|
$7.90 |
Electricity Fees | $4,720 | - |
|
- |
Natural Gas | $91,513 | 10,132 |
MMBtu
|
$9.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,960 | $16,317 | n/a |
$3,441
105,561
kWh
|
$2,129
-
kW-mo/yr
|
$390 | - |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $4,125 | $3,106 | - | - | - |
$4,125
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,323 | $7,734 |
$1,592
48,825
kWh
|
$1,514
-
kW-mo/yr
|
$217 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $987 | $196 |
$922
28,295
kWh
|
- | $65 | - | |
05 | 2.2135: Repair and eliminate steam leaks | $967 | $67 | - | - | - |
$967
-
MMBtu
|
|
06 | 2.7261: Install timers and/or thermostats | $434 | $472 |
$406
12,440
kWh
|
- | $28 | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $61 | $140 |
$37
1,137
kWh
|
$20
-
kW-mo/yr
|
$4 | - | |
TOTAL RECOMMENDED | $15,857 | $28,032 |
$6,398
196,258
kWh
|
$3,663
-
kW-mo/yr
|
$704 |
$5,092
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs