Assessment Year 2003
Principal Product Rubber Industrial Tires
NAICS 326211: Tire Manufacturing (except Retreading)
SIC 3011: Tires and Inner Tubes
Sales Range $5
M
to 10
M
# of Employees 26
Plant Area 110,000
ft2
Annual Production 80,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $33,187 711,640
kWh
Electricity Demand $21,871 2,768
kW-mo/yr
Electricity Fees $4,720 -
Natural Gas $91,513 10,132
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,857 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,960 $16,317 n/a $3,441
105,561
kWh
$2,129
-
kW-mo/yr
$390 -
02 2.2414: Use waste heat from hot flue gases to preheat $4,125 $3,106 - - - $4,125
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,323 $7,734 $1,592
48,825
kWh
$1,514
-
kW-mo/yr
$217 -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $987 $196 $922
28,295
kWh
- $65 -
05 2.2135: Repair and eliminate steam leaks $967 $67 - - - $967
-
MMBtu
06 2.7261: Install timers and/or thermostats $434 $472 $406
12,440
kWh
- $28 -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $61 $140 $37
1,137
kWh
$20
-
kW-mo/yr
$4 -
TOTAL RECOMMENDED $15,857 $28,032 $6,398
196,258
kWh
$3,663
-
kW-mo/yr
$704 $5,092
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs