Assessment Year | 2003 |
---|---|
Principal Product | Wooden Furniture |
NAICS | 337122: Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
250,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $131,970 | 3,987,000 |
kWh
|
$0.033 |
Electricity Demand | $182,564 | 18,790 |
kW-mo/yr
|
$9.72 |
Electricity Fees | $6,545 | - |
|
- |
Natural Gas | $17,516 | 2,286 |
MMBtu
|
$7.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,252 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $19,277 | - | - |
$18,992
-
kW-mo/yr
|
$285 | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,782 | $5,356 |
$2,182
65,911
kWh
|
$7,454
-
kW-mo/yr
|
$146 | |
03 | 2.7231: Use radiant heater for spot heating | $2,347 | $400 |
$477
14,400
kWh
|
$1,836
-
kW-mo/yr
|
$34 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,123 | $477 |
$2,091
62,211
kWh
|
- | $32 | |
05 | 2.4239: Eliminate or reduce compressed air usage | $1,437 | $742 |
$1,416
42,786
kWh
|
- | $21 | |
06 | 2.7261: Install timers and/or thermostats | $494 | $708 |
$487
15,165
kWh
|
- | $7 | |
TOTAL RECOMMENDED | $35,460 | $7,683 |
$6,653
200,473
kWh
|
$28,282
-
kW-mo/yr
|
$525 | ||
TOTAL IMPLEMENTED | $14,252 | $6,233 |
$4,750
142,522
kWh
|
$9,290
-
kW-mo/yr
|
$212 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs