Assessment Year | 2002 |
---|---|
Principal Product | Industrial handling equipment |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 62 |
Plant Area |
68,000
ft2
|
Annual Production | 4,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,364 | 808,560 |
kWh
|
$0.043 |
Electricity Demand | $21,196 | 3,533 |
kW-mo/yr
|
$6.00 |
Electricity Fees | $7,366 | - |
|
- |
Natural Gas | $5,246 | 398 |
MMBtu
|
$13.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,696 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,204 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $2,668 | $2,700 | - | $2,668 | - | |
02 | 2.7261: Install timers and/or thermostats | $919 | $591 |
$906
21,216
kWh
|
$13 | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $244 | $129 |
$240
5,644
kWh
|
$4 | - | |
04 | 3.5316: Contract a wood pallet recycling company | $960 | - | - | - |
$960
-
lb
|
|
05 | 3.1191: Change procedures / equipment / operating conditions | $905 | $374 | - | - |
$905
-
lb
|
|
TOTAL RECOMMENDED | $5,696 | $3,794 |
$1,146
26,860
kWh
|
$2,685 |
$1,865
-
lb
|
||
TOTAL IMPLEMENTED | $1,204 | $129 |
$240
5,644
kWh
|
$4 |
$960
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs