Assessment Year | 2002 |
---|---|
Principal Product | Linerboard |
NAICS |
n/a
|
SIC | 2621: Paper Mills |
Sales Range | $100 M to 500M |
# of Employees | 560 |
Plant Area |
28,750,000
ft2
|
Annual Production | 1,000,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,429,444 | 214,773,450 |
kWh
|
$0.021 |
Electricity Demand | $1,843,512 | 217,652 |
kW-mo/yr
|
$8.47 |
Electricity Fees | $2,179,504 | - |
|
- |
Natural Gas | $24,782,042 | 4,588,840 |
MMBtu
|
$5.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,279 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $11,647 | $9,315 |
$7,917
306,858
kWh
|
$3,559
-
kW-mo/yr
|
$171 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $75,640 | $145,111 |
$51,412
1,991,793
kWh
|
$23,111
-
kW-mo/yr
|
$1,117 | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,132 | $35,712 |
$18,849
730,363
kWh
|
- | $283 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,267 | $340 |
$5,190
201,055
kWh
|
- | $77 | |
05 | 2.7261: Install timers and/or thermostats | $1,593 | $1,063 |
$1,570
60,668
kWh
|
- | $23 | |
TOTAL RECOMMENDED | $113,279 | $191,541 |
$84,938
3,290,737
kWh
|
$26,670
-
kW-mo/yr
|
$1,671 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs