Assessment Year 2002
Principal Product Automotive injection molded parts
NAICS
n/a
SIC 3647: Vehicular Lighting Equipment
Sales Range $100
M
to 500
M
# of Employees 110
Plant Area 200,100
ft2
Annual Production 6,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $81,666 9,951,055
kWh
Electricity Demand $129,440 27,774
kW-mo/yr
Electricity Fees $259,948 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $87,246 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $53,706

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings
01 2.7241: Install outside air damper / economizer on hvac unit $51,081 $50,126 $7,524
1,584,115
kWh
$43,557
02 2.7261: Install timers and/or thermostats $33,540 $3,025 $4,940
1,040,152
kWh
$28,600
03 2.2511: Insulate bare equipment $2,123 $120 $313
65,944
kWh
$1,810
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $502 $161 $74
15,533
kWh
$428
TOTAL RECOMMENDED $87,246 $53,432 $12,851
2,705,744
kWh
$74,395
TOTAL IMPLEMENTED $53,706 $50,407 $7,911
1,665,592
kWh
$45,795
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs