| Assessment Year | 1993 |
|---|---|
| Principal Product | Rough and planed lumber |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 100,000
thousand feet
|
| Production Hrs. Annual | 4,482
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $202,854 | 5,900,938 |
kWh
|
$0.034 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,141 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,141 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,108 | - |
$2,108
41,911
kWh
|
|
| 02 | 2.3212: Optimize plant power factor | $12,645 | $9,750 |
$12,645
-
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $388 | $1,922 |
$388
8,792
kWh
|
|
| TOTAL RECOMMENDED | $15,141 | $11,672 |
$15,141
50,703
kWh
|
||
| TOTAL IMPLEMENTED | $15,141 | $11,672 |
$15,141
50,703
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs