Assessment Year | 2001 |
---|---|
Principal Product | Optical network cable |
NAICS |
n/a
|
SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 23 |
Plant Area |
60,000
ft2
|
Annual Production | 400,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,988 | 697,200 |
kWh
|
$0.059 |
Electricity Demand | $53 | 2,256 |
kW-mo/yr
|
$0.023 |
Electricity Fees | $6,499 | - |
|
- |
Natural Gas | $7,585 | 1,301 |
MMBtu
|
$5.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,871 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,583 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $2,288 | $473 |
$1,856
35,595
kWh
|
$432 | |
02 | 2.7124: Make a practice of turning off lights when not needed | $8,020 | $100 |
$6,505
124,781
kWh
|
$1,515 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $234 | $128 |
$106
2,035
kWh
|
$128 | |
04 | 2.7124: Make a practice of turning off lights when not needed | $1,329 | $729 |
$1,078
20,683
kWh
|
$251 | |
TOTAL RECOMMENDED | $11,871 | $1,430 |
$9,545
183,094
kWh
|
$2,326 | ||
TOTAL IMPLEMENTED | $9,583 | $957 |
$7,689
147,499
kWh
|
$1,894 |