| Assessment Year | 2001 |
|---|---|
| Principal Product | Custom molded plastic parts |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 25 |
| Plant Area |
28,850
ft2
|
| Annual Production | 81,000,000
pieces
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,592 | 2,430,720 |
kWh
|
$0.035 |
| Electricity Demand | $45,285 | 6,004 |
kW-mo/yr
|
$7.54 |
| Electricity Fees | $2,531 | - |
|
- |
| LPG | $9,418 | 597 |
MMBtu
|
$15.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,296 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $1,548 | $503 |
$1,525
45,889
kWh
|
- | $23 | - | - | |
| 02 | 2.7135: Install occupancy sensors | $208 | $215 |
$205
6,167
kWh
|
- | $3 | - | - | |
| 03 | 2.7261: Install timers and/or thermostats | $180 | $236 |
$177
5,338
kWh
|
- | $3 | - | - | |
| 04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $9,552 | $3,309 |
$7,401
222,723
kWh
|
$2,010
-
kW-mo/yr
|
$141 | - | - | |
| 05 | 2.7122: Disconnect ballasts | $571 | $160 |
$268
8,064
kWh
|
$295
-
kW-mo/yr
|
$8 | - | - | |
| 06 | 3.6124: Burn waste oil for heat | $2,078 | $4,461 | - | - | - | - |
$2,078
-
gal
|
|
| 07 | 4.812: Apply for investment incentives | $159 | $50 | - | - | - |
$159
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $14,296 | $8,934 |
$9,576
288,181
kWh
|
$2,305
-
kW-mo/yr
|
$178 |
$159
-
Tgal
|
$2,078
-
gal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs