Assessment Year | 1998 |
---|---|
Principal Product | Torque Converters |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
40,000
ft2
|
Annual Production | 33,540
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,209 | 918,523 |
kWh
|
$0.039 |
Electricity Demand | $35,335 | 4,475 |
kW-mo/yr
|
$7.90 |
Electricity Fees | $1,317 | - |
|
- |
Natural Gas | $16,439 | 2,573 |
MMBtu
|
$6.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $157,087 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,207 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $2,591 | $1,650 |
$2,552
75,322
kWh
|
$39 | - | - | - | - | - | |
02 | 2.2437: Recover waste heat from equipment | $4,475 | $2,965 | - | - |
$4,475
-
MMBtu
|
- | - | - | - | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,028 | $1,255 |
$1,968
58,030
kWh
|
$60 | - | - | - | - | - | |
04 | 2.7245: Use direct air supply to exhaust hoods | $2,024 | $1,688 |
$895
26,377
kWh
|
$13 |
$1,116
-
MMBtu
|
- | - | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $1,206 | $1,478 |
$1,189
35,170
kWh
|
$17 | - | - | - | - | - | |
06 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $271 | $549 |
$267
7,913
kWh
|
$4 | - | - | - | - | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $849 | $25 | - | - | - | - | $849 | - | - | |
08 | 3.7196: Use re-usable filters | $1,329 | $1,476 | - | - | - | - | - | $1,329 | - | |
09 | 4.632: Change operating conditions | $20,640 | $3,915 | - | - | - | - | $8,640 | - | $12,000 | |
10 | 4.111: Add equipment/ operators to reduce production bottleneck | $121,674 | $11,729 | - | - | - | $28,958 | $92,716 | - | - | |
TOTAL RECOMMENDED | $157,087 | $26,730 |
$6,871
202,812
kWh
|
$133 |
$5,591
-
MMBtu
|
$28,958 | $102,205 | $1,329 | $12,000 | ||
TOTAL IMPLEMENTED | $31,207 | $12,245 |
$4,903
144,782
kWh
|
$73 |
$5,591
-
MMBtu
|
- | $8,640 | - | $12,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs