Assessment Year | 1998 |
---|---|
Principal Product | textile felts |
NAICS |
n/a
|
SIC | 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk |
Sales Range | $10 M to 50M |
# of Employees | 172 |
Plant Area |
250,000
ft2
|
Annual Production | 720,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $381,740 | 12,138,042 |
kWh
|
$0.031 |
Electricity Demand | $234,606 | 24,274 |
kW-mo/yr
|
$9.66 |
Electricity Fees | $9,356 | - |
|
- |
Natural Gas | $170,652 | 47,895 |
MMBtu
|
$3.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $596,085 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $554,157 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $22,934 | $8,025 | - | - | $22,934 | - | - | - | |
02 | 2.6218: Turn off equipment when not in use | $16,041 | - |
$11,127
353,751
kWh
|
$4,914
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $3,038 | $1,930 |
$3,038
96,717
kWh
|
- | - | - | - | - | |
04 | 2.2211: Use optimum temperature | $17,981 | - | - | - | - |
$17,981
-
MMBtu
|
- | - | |
05 | 2.2164: Turn off steam tracing during mild weather | $5,726 | - | - | - | - |
$5,726
-
MMBtu
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $7,306 | $47 | - | - | - |
$7,306
-
MMBtu
|
- | - | |
07 | 2.2437: Recover waste heat from equipment | $4,227 | $8,447 | - | - | - |
$4,227
-
MMBtu
|
- | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,767 | $22,372 |
$14,767
469,519
kWh
|
- | - | - | - | - | |
09 | 3.5313: Increase amount of waste recovered for resale | $7,369 | - | - | - | - | - |
$7,369
-
lb
|
- | |
10 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $7,480 | $6,500 | - | - | - | - |
$7,480
-
lb
|
- | |
11 | 4.452: Eliminate shift | $489,216 | - | - | - | - | - | - | $489,216 | |
TOTAL RECOMMENDED | $596,085 | $47,321 |
$28,932
919,987
kWh
|
$4,914
-
kW-mo/yr
|
$22,934 |
$35,240
-
MMBtu
|
$14,849
-
lb
|
$489,216 | ||
TOTAL IMPLEMENTED | $554,157 | $8,477 |
$14,165
450,468
kWh
|
$4,914
-
kW-mo/yr
|
- |
$31,013
-
MMBtu
|
$14,849
-
lb
|
$489,216 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs