Assessment Year | 1997 |
---|---|
Principal Product | Foam |
NAICS |
n/a
|
SIC | 3086: Plastics Foam Products |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
369,000
ft2
|
Annual Production | 144,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,840 | 3,250,879 |
kWh
|
$0.031 |
Electricity Demand | $73,091 | 8,382 |
kW-mo/yr
|
$8.72 |
Electricity Fees | $2,609 | - |
|
- |
Natural Gas | $21,037 | 4,069 |
MMBtu
|
$5.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,296 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,787 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $393 | $688 |
$393
12,603
kWh
|
- | - | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $2,900 | $130 |
$1,782
57,444
kWh
|
$1,118
-
kW-mo/yr
|
- | - | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $2,509 | $6,600 | - | - |
$2,509
-
MMBtu
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $11,663 | $4,770 | - | - |
$11,663
-
MMBtu
|
- | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $7,250 | $6,500 | - | - | - | - | $7,250 | |
06 | 4.322: Eliminate old stock and modify inventory control | $27,581 | $3,182 | - | - | - | $16,911 | $10,670 | |
TOTAL RECOMMENDED | $52,296 | $21,870 |
$2,175
70,047
kWh
|
$1,118
-
kW-mo/yr
|
$14,172
-
MMBtu
|
$16,911 | $17,920 | ||
TOTAL IMPLEMENTED | $49,787 | $15,270 |
$2,175
70,047
kWh
|
$1,118
-
kW-mo/yr
|
$11,663
-
MMBtu
|
$16,911 | $17,920 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs