| Assessment Year | 1997 |
|---|---|
| Principal Product | Conveyor Systems |
| NAICS |
n/a
|
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 380 |
| Plant Area |
304,000
ft2
|
| Annual Production | 35,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $243,110 | 7,837,339 |
kWh
|
$0.031 |
| Electricity Demand | $160,954 | 17,794 |
kW-mo/yr
|
$9.05 |
| Electricity Fees | $6,165 | - |
|
- |
| Natural Gas | $142,844 | 48,497 |
MMBtu
|
$2.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $136,155 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $32,037 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $4,514 | $4,620 |
$4,514
145,662
kWh
|
- | - | - | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,653 | $30,962 |
$9,869
317,995
kWh
|
$6,784
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.7134: Use photocell controls | $1,556 | $616 |
$1,556
50,117
kWh
|
- | - | - | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,390 | $541 |
$962
31,067
kWh
|
$428
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $9,480 | $955 | - | - |
$9,480
-
MMBtu
|
- | - | - | - | |
| 06 | 3.5316: Contract a wood pallet recycling company | $8,888 | - | - | - | - | - |
$8,888
-
lb
|
- | - | |
| 07 | 3.8141: Regenerate cleaning solvent on-site and reuse | $12,074 | $13,000 | - | - | - |
$2,189
-
gal
|
- | - | $9,885 | |
| 08 | 4.452: Eliminate shift | $81,600 | - | - | - | - | - | - | $81,600 | - | |
| TOTAL RECOMMENDED | $136,155 | $50,694 |
$16,901
544,841
kWh
|
$7,212
-
kW-mo/yr
|
$9,480
-
MMBtu
|
$2,189
-
gal
|
$8,888
-
lb
|
$81,600 | $9,885 | ||
| TOTAL IMPLEMENTED | $32,037 | $37,078 |
$15,345
494,724
kWh
|
$7,212
-
kW-mo/yr
|
$9,480
-
MMBtu
|
- | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs