Assessment Year | 1996 |
---|---|
Principal Product | Dump Bodies, Dump Trailers,Spreaders, Hoists |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
120,000
ft2
|
Annual Production | 60,000
ton
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,517 | 1,541,618 |
kWh
|
$0.042 |
Electricity Demand | $39,702 | 6,425 |
kW-mo/yr
|
$6.18 |
Electricity Fees | $(-10,457.0) | - |
|
- |
Natural Gas | $6,616 | 1,427 |
MMBtu
|
$4.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,014 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $376 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $4,278 | $3,000 | - |
$4,278
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,335 | $4,731 |
$1,054
24,912
kWh
|
$317
-
kW-mo/yr
|
$(-36.0) | - | |
03 | 2.7261: Install timers and/or thermostats | $376 | $696 |
$390
9,086
kWh
|
- | $(-14.0) | - | |
04 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,025 | $6,500 | - | - | - | $2,025 | |
TOTAL RECOMMENDED | $8,014 | $14,927 |
$1,444
33,998
kWh
|
$4,595
-
kW-mo/yr
|
$(-50.0) | $2,025 | ||
TOTAL IMPLEMENTED | $376 | $696 |
$390
9,086
kWh
|
- | $(-14.0) | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs