Assessment Year | 1995 |
---|---|
Principal Product | Men's Work Pants |
NAICS |
n/a
|
SIC | 2326: Men's and Boys' Work Clothing |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
45,000
ft2
|
Annual Production | 4,147,200
pieces
|
Production Hrs. Annual | 3,800
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $187,616 | 3,184,056 |
kWh
|
$0.059 |
Natural Gas | $35,662 | 10,869 |
MMBtu
|
$3.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,029 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,775 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $5,016 | $10,000 | - |
$5,016
-
MMBtu
|
|
02 | 2.3212: Optimize plant power factor | $5,174 | $3,750 |
$5,174
-
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,539 | $500 |
$1,539
24,326
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,429 | $1,436 |
$4,429
66,237
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $1,563 | - |
$1,563
21,102
kWh
|
- | |
06 | 2.2136: Install / repair insulation on steam lines | $675 | $1,540 |
$361
11,137
kWh
|
$314
-
MMBtu
|
|
07 | 2.4133: Use most efficient type of electric motors | $633 | $1,800 |
$633
6,155
kWh
|
- | |
TOTAL RECOMMENDED | $19,029 | $19,026 |
$13,699
128,957
kWh
|
$5,330
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,775 | $7,486 |
$11,775
96,718
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs